Model No: Product Category: 1A Single Phase EMI Filters

1A Single Phase EMI Filter for Electronic & Industrial Equipment

DOREXS provides 1A single-phase EMI filters for low-current AC power inputs where conducted electromagnetic interference must be reduced before it enters or leaves the equipment.
Multiple 1A configurations are available for 110/115–250 VAC systems, including chassis-mounted filters, PCB-mounted filters, IEC inlet filters, and integrated power-entry modules.
Rated Current: 1A
Power System: Single Phase AC
Typical Voltage: 110/115–250 VAC
Frequency: 50/60 Hz
Noise Suppression: Common Mode + Differential Mode
Mounting Options: Chassis / PCB / IEC Inlet
Low-Leakage Options: Available by model
Custom Design: Available
Quantity :
Contact Now

Available 1A Single Phase EMI Filter Models

A 1A current rating can be supplied in several mechanical and electrical configurations. The correct filter should therefore be selected according to the equipment power entry, available installation space, leakage-current requirement and required EMI attenuation.

Series

Configuration

Current Range

Typical Voltage

Connection / Mounting

Recommended Use

DAA1General-purpose chassis filter1–10A115/250VACInsert / WireElectronic equipment, appliances, control systems
DAA2Compact high-performance filter1–10A115/250VACInsert / WireCompact equipment and applications requiring enhanced attenuation
DBA3Industrial power line filter1–20A115/250VACBolt / Faston / WireIndustrial and commercial equipment
DAP1PCB-mounted EMI filter1–10A115/250VACPCB PinPCB-integrated power input filtering
DAI1IEC inlet EMI filter1–10AUp to 250VACIEC InletCompact equipment power entry
DBI5Integrated IEC power-entry filter1–10AUp to 275VACIEC Inlet / Fuse / Switch optionsEquipment requiring integrated power entry functions

Not sure which 1A filter is suitable?

Send DOREXS your input voltage, maximum operating current, equipment type, installation method and EMC test problem. Our engineering team can help identify a suitable standard or custom filter configuration.

1A EMI Filter Technical Overview

The electrical specifications of a 1A EMI filter vary according to the selected series and circuit configuration.

Parameter

Available / Typical Specification

Product TypeSingle Phase EMI / EMC Filter
Rated Current1A
Power SystemSingle Phase AC
Operating VoltageTypically 110/115–250VAC; some series support higher maximum operating voltage
Frequency50/60Hz
Noise ModeCommon Mode and Differential Mode
Filter StructureSingle-stage or enhanced filtering configurations depending on series
Leakage CurrentStandard and low-leakage options
InstallationChassis / Panel / PCB / IEC Power Entry
ConnectionFaston / Wire / Bolt / PCB Pin / IEC Inlet
Operating TemperatureTypically -25°C to +85°C depending on model
Compliance OptionscUL / CQC / CE / RoHS depending on series
CustomizationElectrical parameters, terminals, wiring, housing and attenuation performance

Individual model specifications should be confirmed before final equipment design.

How to Choose a 1A Single Phase EMI Filter

Selecting an EMI filter requires more than matching the nominal current rating. The filter must also match the electrical system, EMI spectrum, mechanical installation and safety requirements of the equipment.

1. Confirm the Maximum Operating Current

A 1A EMI filter is suitable when the equipment's maximum continuous operating current remains within the selected filter rating.

Do not select the filter only from the normal operating current. Check:

  • Maximum continuous current

  • Startup or inrush conditions

  • Operating temperature

  • Load variation

If the equipment may exceed 1A under normal operating conditions, select the next appropriate current rating.

2. Confirm the AC Input Voltage

DOREXS 1A single phase filters are available for common AC mains systems such as:

  • 110VAC

  • 115VAC

  • 220VAC

  • 230VAC

  • 250VAC

The exact maximum operating voltage depends on the selected filter series.

3. Choose the Installation Type

Different equipment architectures require different filter constructions.

Chassis-Mounted Filter

Choose DAA1, DAA2 or DBA3 when the filter will be installed inside a metal enclosure or electrical cabinet.

PCB-Mounted Filter

Choose DAP1 when the filter must be integrated directly onto the PCB power input.

IEC Inlet Filter

Choose DAI1 when the AC inlet and EMI filtering function should be integrated at the equipment power entry.

Integrated Power-Entry Filter

Choose DBI5 when IEC inlet, EMI filtering, switching or fuse functions need to be combined into one compact module.

4. Check Leakage Current Requirements

Y-capacitors used for common-mode noise suppression can contribute to earth leakage current.

For applications such as:

  • Medical electronics

  • Laboratory instruments

  • Measurement equipment

  • Sensitive electronic systems

a low-leakage configuration may be required.

DOREXS can evaluate the filter circuit according to the equipment's leakage-current and attenuation requirements.

5. Identify the EMI Frequency Range

Conducted-emission problems do not occur at exactly the same frequencies in every system.

When EMC test data is available, provide the failed frequency range and exceedance level to the filter engineer.

This helps determine whether a standard single-stage design is sufficient or whether stronger low-frequency or wideband attenuation is required.

6. Confirm Grounding and Wiring Conditions

Even a correctly selected EMI filter can perform poorly if it is installed incorrectly.

Filter performance should therefore be evaluated together with:

  • Ground connection

  • Cable routing

  • Line/load separation

  • Filter location

  • Chassis bonding

  • Source and load impedance


Common Mode and Differential Mode EMI Suppression

A single phase EMI filter is typically designed to reduce both major types of conducted interference.

Common Mode Noise

Common-mode interference appears between the power conductors and ground.

A common-mode choke together with suitable capacitors provides a high impedance path to high-frequency interference while allowing the normal 50/60Hz power current to pass.

Differential Mode Noise

Differential-mode interference appears between line and neutral.

Differential inductance and X-capacitor networks can be used to attenuate this noise.

The actual filter circuit varies between DAA1, DAA2, DBA3, DAP1, DAI1 and DBI5 because each series is designed for a different installation and performance requirement.


Dimensions & Installation Options

DOREXS offers several mechanical structures for 1A EMI filter applications.

DAA1

Compact chassis-mounted configuration with Faston or wire connection options.

DAA1 dimensional drawing 1DAA1 dimensional drawing 2


DAA2

Compact single phase filter suitable for equipment with restricted installation space and applications requiring strong conducted-noise suppression.

DAA2 dimensional drawing


DBA3

Industrial chassis filter with flexible bolt, blade or wire connection options.

DBA3 dimensional drawing


DAP1

PCB-mounted filter designed for direct integration into electronic equipment power-input circuits.

DAP1 dimensional drawing


DAI1

IEC inlet filter that combines the equipment AC power inlet with EMI filtering.

DAI1 dimensional drawing


DBI5

Integrated IEC power-entry configuration with switch and fuse options.

DBI5 dimensional drawing


Always confirm the selected model drawing before mechanical design or enclosure tooling.


Circuit Diagrams

Different 1A EMI filter series use different circuit structures depending on attenuation, leakage-current and installation requirements.

DAA1 circuit diagrams

 
DAA2 circuit diagrams

 
DBA3 circuit diagrams

 
DAA1DAA2DBA3
DAP1 circuit diagrams

 
DAI1 circuit diagrams

 
DBI5 circuit diagrams

 
DAP1DAI1DBI5

Circuit selection should consider:

  • Required common-mode attenuation

  • Required differential-mode attenuation

  • Leakage-current limit

  • Equipment grounding system

  • EMC failure frequency

  • Installation environment

For applications with specific EMC test failures, DOREXS can evaluate the existing noise spectrum before recommending a filter circuit.


Insertion Loss Performance

DOREXS 1A single phase EMI filters are designed to attenuate conducted interference on AC power lines.

Depending on the selected series, the filter can help reduce:

  • Common-mode conducted noise

  • Differential-mode conducted noise

  • Switching power supply interference

  • High-frequency noise transmitted through AC input wiring

EMI filter insertion loss diagram

Insertion-loss curves are measured under defined test conditions. Actual attenuation after installation can differ because real equipment source impedance, load impedance, grounding, cable layout and enclosure construction are different from standardized laboratory conditions.

For this reason, EMC test results from the actual equipment are especially useful when selecting a filter for an existing compliance problem.


Typical Applications for 1A EMI Filters

A 1A power line EMI filter is mainly suited to low-current AC input circuits and auxiliary power systems.

Application Scenarios for Single Phase Power Line EMI Filters

Industrial Control Electronics

Suitable for low-current control circuits, PLC-related equipment, controller power supplies and auxiliary electronics where switching noise may propagate through the AC input.

Switching Power Supplies

A 1A AC EMI filter can be installed at the power entry of low-power switching supplies to reduce conducted emissions generated by high-frequency switching.

Laboratory & Measurement Equipment

Test instruments and measurement systems may require power-line filtering to reduce interference entering or leaving sensitive electronics.

Communication Equipment

Compact power-line filters can help reduce conducted interference in communication terminals, network equipment and related low-current power supplies.

Medical Electronics

Low-leakage filter configurations can be evaluated for medical and safety-sensitive electronic equipment where both EMC performance and leakage-current limits must be considered.

PCB-Based Electronic Equipment

DAP1 provides a PCB-mount option where space is limited and the EMI filter must be integrated directly into the electronic assembly.

IEC Power-Entry Equipment

DAI1 and DBI5 are suitable where the equipment requires an IEC power inlet together with EMI filtering at the enclosure entry point.

VFD, Servo & Industrial Drive Control Circuits

A 1A filter is generally not intended for the main high-current power input of a VFD or servo drive.

However, it may be suitable for auxiliary power supplies, controllers, communication modules or other low-current circuits within the system.


Installation Guidelines for Better EMC Performance

Filter selection and installation should be considered together.

For better conducted EMI suppression:

  1. Install the filter as close as practical to the AC power entry.

  2. Keep unfiltered and filtered wiring physically separated.

  3. Keep input and output wires short.

  4. Avoid routing filter input and output cables parallel to each other.

  5. Provide a short, low-impedance connection between the filter housing and metal chassis where grounding is required.

  6. Avoid allowing unfiltered wiring to couple noise back into the filtered side.

  7. Confirm leakage-current requirements before increasing Y-capacitance.

  8. Re-test the equipment after installation under representative operating conditions.

If conducted emissions remain above the required limit, the filter should not automatically be replaced with a larger current rating. The noise frequency, attenuation requirement and installation layout should first be evaluated.


Standard vs Low-Leakage 1A EMI Filters

Standard EMI filters normally use line-to-ground capacitors to improve common-mode attenuation.

In applications with strict leakage-current requirements, a lower Y-capacitance configuration may be necessary.

This creates an engineering trade-off:

Higher common-mode attenuation ↔ Lower leakage current

For medical electronics, laboratory equipment and other safety-sensitive systems, DOREXS can evaluate the leakage-current requirement before selecting or modifying the filter circuit.


Custom 1A EMI Filter Solutions

When a standard filter cannot meet the electrical, mechanical or EMC requirements of the equipment, DOREXS can evaluate a custom design.

Customization can include:

  • Filter circuit configuration

  • Common-mode attenuation

  • Differential-mode attenuation

  • Leakage-current optimization

  • Terminal type

  • Wire length

  • Connector type

  • Mechanical dimensions

  • Housing configuration

  • PCB mounting structure

  • IEC power-entry configuration

  • OEM labeling

For an EMC troubleshooting project, providing the following information can significantly improve filter selection:

Input Voltage + Maximum Current + Equipment Type + EMC Test Curve + Failed Frequency Range + Installation Space + Leakage-Current Requirement


Quality, Testing & Compliance

DOREXS single phase EMI filter series are manufactured and inspected according to the requirements of the selected product and application.

Available evaluation and quality-control items may include:

  • Electrical performance inspection

  • Withstand-voltage testing

  • Insulation inspection

  • Leakage-current testing

  • Mechanical inspection

  • Insertion-loss evaluation

  • Final product inspection

DOREXS single phase emi filter certifications

Certifications and approvals vary by product series. Selected DOREXS EMI filters are available with cUL, CQC, CE and RoHS compliance options.

Always confirm certification requirements for the exact model selected for your project.


Related Single Phase EMI Filters

If 1A does not match the equipment load, choose the appropriate current rating based on the maximum operating conditions.

3A Single Phase EMI Filter
For low-power electronic and control equipment requiring additional current capacity.

6A Single Phase EMI Filter
Suitable for medium-power electronic equipment and industrial control systems.

10A Single Phase EMI Filter
For higher-current single phase equipment, switching power supplies and industrial electronics.

20A+ Single Phase EMI Filters
Available for industrial equipment requiring higher power handling and conducted EMI suppression.

Explore the complete Single Phase EMI Filter range to compare available current ratings and mechanical configurations.


Why Choose DOREXS?

DOREXS develops and manufactures EMI filtering and power-quality products for industrial and electronic equipment.

Our support includes:

  • Standard EMI filter products

  • OEM / ODM manufacturing

  • Custom EMI filter development

  • Electrical and mechanical customization

  • EMC troubleshooting support

  • Filter selection assistance

  • Technical documentation and datasheets

Rather than selecting a filter only from voltage and current, our engineers can evaluate the equipment architecture, noise characteristics and installation conditions when additional EMC support is required.


Frequently Asked Questions

What is a 1A single phase EMI filter?

A 1A single phase EMI filter is a power-line interference suppression device designed for single phase AC circuits with a rated current of approximately 1 amp. It is used to attenuate conducted common-mode and differential-mode noise while allowing normal AC power to pass to the load.

Can a 1A EMI filter be used on 220V or 230V equipment?

Yes, provided the selected filter model is rated for the equipment's operating voltage. DOREXS offers multiple 1A filter series for common 110/115–250VAC single phase systems.

Is a 1A filter suitable if my equipment normally draws 0.9A?

Selection should not be based only on normal current. Maximum continuous current, startup conditions, temperature and load variation should also be considered. If the equipment may exceed the filter rating, a higher-current model should be evaluated.

What is the difference between DAA1, DAA2 and DBA3?

All three can be used in single phase AC power-line filtering, but their mechanical structures, connection methods and filter configurations differ. DAA1 is a general-purpose compact chassis filter, DAA2 provides compact enhanced filtering options, and DBA3 provides more flexible industrial connection methods.

When should I use the DAP1 PCB EMI filter?

DAP1 is suitable when EMI filtering must be integrated directly onto the PCB and an external chassis-mounted filter is not preferred.

When should I use an IEC inlet EMI filter?

An IEC inlet filter such as DAI1 is useful when the AC power inlet and EMI filter should be integrated at the equipment power entry. DBI5 can be considered when additional switch or fuse integration is required.

Are low-leakage 1A EMI filters available?

Yes. Low-leakage configurations are available for selected series. The appropriate design depends on the required leakage-current limit and the amount of common-mode attenuation required.

Does a higher-current EMI filter provide better filtering?

Not necessarily. Current rating indicates how much load current the filter can safely carry; it does not by itself determine attenuation performance. Filter circuit structure, component values, noise frequency and installation conditions are also important.

How do I know how much insertion loss I need?

If the equipment has already undergone EMC testing, provide the conducted-emission curve, failed frequency range and exceedance level. These measurements help determine how much attenuation is required in the relevant frequency band.

Can DOREXS customize a 1A EMI filter?

Yes. Electrical parameters, leakage current, terminals, wiring, housing dimensions and filter configuration can be evaluated according to the equipment and EMC requirements.


Need Help Selecting a 1A EMI Filter?

Send your project requirements to the DOREXS engineering team:

  • Voltage
  • Maximum Current
  • Equipment Type
  • EMC Test Result or Failed Frequency
  • Installation Space
  • Connection Method
  • Leakage-Current Requirement

We can evaluate whether a standard DAA1, DAA2, DBA3, DAP1, DAI1 or DBI5 configuration is suitable, or whether a custom EMI filter is required.

Request a Quote | Ask an Engineer