1A Single Phase EMI Filter for Electronic & Industrial Equipment
Multiple 1A configurations are available for 110/115–250 VAC systems, including chassis-mounted filters, PCB-mounted filters, IEC inlet filters, and integrated power-entry modules.
Rated Current: 1A
Power System: Single Phase AC
Typical Voltage: 110/115–250 VAC
Frequency: 50/60 Hz
Noise Suppression: Common Mode + Differential Mode
Mounting Options: Chassis / PCB / IEC Inlet
Low-Leakage Options: Available by model
Custom Design: Available
Available 1A Single Phase EMI Filter Models
A 1A current rating can be supplied in several mechanical and electrical configurations. The correct filter should therefore be selected according to the equipment power entry, available installation space, leakage-current requirement and required EMI attenuation.
Series | Configuration | Current Range | Typical Voltage | Connection / Mounting | Recommended Use |
|---|---|---|---|---|---|
| DAA1 | General-purpose chassis filter | 1–10A | 115/250VAC | Insert / Wire | Electronic equipment, appliances, control systems |
| DAA2 | Compact high-performance filter | 1–10A | 115/250VAC | Insert / Wire | Compact equipment and applications requiring enhanced attenuation |
| DBA3 | Industrial power line filter | 1–20A | 115/250VAC | Bolt / Faston / Wire | Industrial and commercial equipment |
| DAP1 | PCB-mounted EMI filter | 1–10A | 115/250VAC | PCB Pin | PCB-integrated power input filtering |
| DAI1 | IEC inlet EMI filter | 1–10A | Up to 250VAC | IEC Inlet | Compact equipment power entry |
| DBI5 | Integrated IEC power-entry filter | 1–10A | Up to 275VAC | IEC Inlet / Fuse / Switch options | Equipment requiring integrated power entry functions |
Not sure which 1A filter is suitable?
Send DOREXS your input voltage, maximum operating current, equipment type, installation method and EMC test problem. Our engineering team can help identify a suitable standard or custom filter configuration.
1A EMI Filter Technical Overview
The electrical specifications of a 1A EMI filter vary according to the selected series and circuit configuration.
Parameter | Available / Typical Specification |
|---|---|
| Product Type | Single Phase EMI / EMC Filter |
| Rated Current | 1A |
| Power System | Single Phase AC |
| Operating Voltage | Typically 110/115–250VAC; some series support higher maximum operating voltage |
| Frequency | 50/60Hz |
| Noise Mode | Common Mode and Differential Mode |
| Filter Structure | Single-stage or enhanced filtering configurations depending on series |
| Leakage Current | Standard and low-leakage options |
| Installation | Chassis / Panel / PCB / IEC Power Entry |
| Connection | Faston / Wire / Bolt / PCB Pin / IEC Inlet |
| Operating Temperature | Typically -25°C to +85°C depending on model |
| Compliance Options | cUL / CQC / CE / RoHS depending on series |
| Customization | Electrical parameters, terminals, wiring, housing and attenuation performance |
Individual model specifications should be confirmed before final equipment design.
How to Choose a 1A Single Phase EMI Filter
Selecting an EMI filter requires more than matching the nominal current rating. The filter must also match the electrical system, EMI spectrum, mechanical installation and safety requirements of the equipment.
1. Confirm the Maximum Operating Current
A 1A EMI filter is suitable when the equipment's maximum continuous operating current remains within the selected filter rating.
Do not select the filter only from the normal operating current. Check:
Maximum continuous current
Startup or inrush conditions
Operating temperature
Load variation
If the equipment may exceed 1A under normal operating conditions, select the next appropriate current rating.
2. Confirm the AC Input Voltage
DOREXS 1A single phase filters are available for common AC mains systems such as:
110VAC
115VAC
220VAC
230VAC
250VAC
The exact maximum operating voltage depends on the selected filter series.
3. Choose the Installation Type
Different equipment architectures require different filter constructions.
Chassis-Mounted Filter
Choose DAA1, DAA2 or DBA3 when the filter will be installed inside a metal enclosure or electrical cabinet.
PCB-Mounted Filter
Choose DAP1 when the filter must be integrated directly onto the PCB power input.
IEC Inlet Filter
Choose DAI1 when the AC inlet and EMI filtering function should be integrated at the equipment power entry.
Integrated Power-Entry Filter
Choose DBI5 when IEC inlet, EMI filtering, switching or fuse functions need to be combined into one compact module.
4. Check Leakage Current Requirements
Y-capacitors used for common-mode noise suppression can contribute to earth leakage current.
For applications such as:
Medical electronics
Laboratory instruments
Measurement equipment
Sensitive electronic systems
a low-leakage configuration may be required.
DOREXS can evaluate the filter circuit according to the equipment's leakage-current and attenuation requirements.
5. Identify the EMI Frequency Range
Conducted-emission problems do not occur at exactly the same frequencies in every system.
When EMC test data is available, provide the failed frequency range and exceedance level to the filter engineer.
This helps determine whether a standard single-stage design is sufficient or whether stronger low-frequency or wideband attenuation is required.
6. Confirm Grounding and Wiring Conditions
Even a correctly selected EMI filter can perform poorly if it is installed incorrectly.
Filter performance should therefore be evaluated together with:
Ground connection
Cable routing
Line/load separation
Filter location
Chassis bonding
Source and load impedance
Common Mode and Differential Mode EMI Suppression
A single phase EMI filter is typically designed to reduce both major types of conducted interference.
Common Mode Noise
Common-mode interference appears between the power conductors and ground.
A common-mode choke together with suitable capacitors provides a high impedance path to high-frequency interference while allowing the normal 50/60Hz power current to pass.
Differential Mode Noise
Differential-mode interference appears between line and neutral.
Differential inductance and X-capacitor networks can be used to attenuate this noise.
The actual filter circuit varies between DAA1, DAA2, DBA3, DAP1, DAI1 and DBI5 because each series is designed for a different installation and performance requirement.
Dimensions & Installation Options
DOREXS offers several mechanical structures for 1A EMI filter applications.
DAA1
Compact chassis-mounted configuration with Faston or wire connection options.
DAA2
Compact single phase filter suitable for equipment with restricted installation space and applications requiring strong conducted-noise suppression.
DBA3
Industrial chassis filter with flexible bolt, blade or wire connection options.
DAP1
PCB-mounted filter designed for direct integration into electronic equipment power-input circuits.
DAI1
IEC inlet filter that combines the equipment AC power inlet with EMI filtering.
DBI5
Integrated IEC power-entry configuration with switch and fuse options.
Always confirm the selected model drawing before mechanical design or enclosure tooling.
Circuit Diagrams
Different 1A EMI filter series use different circuit structures depending on attenuation, leakage-current and installation requirements.
![]() | ![]() | ![]() |
| DAA1 | DAA2 | DBA3 |
![]() | ![]() | ![]() |
| DAP1 | DAI1 | DBI5 |
Circuit selection should consider:
Required common-mode attenuation
Required differential-mode attenuation
Leakage-current limit
Equipment grounding system
EMC failure frequency
Installation environment
For applications with specific EMC test failures, DOREXS can evaluate the existing noise spectrum before recommending a filter circuit.
Insertion Loss Performance
DOREXS 1A single phase EMI filters are designed to attenuate conducted interference on AC power lines.
Depending on the selected series, the filter can help reduce:
Common-mode conducted noise
Differential-mode conducted noise
Switching power supply interference
High-frequency noise transmitted through AC input wiring

Insertion-loss curves are measured under defined test conditions. Actual attenuation after installation can differ because real equipment source impedance, load impedance, grounding, cable layout and enclosure construction are different from standardized laboratory conditions.
For this reason, EMC test results from the actual equipment are especially useful when selecting a filter for an existing compliance problem.
Typical Applications for 1A EMI Filters
A 1A power line EMI filter is mainly suited to low-current AC input circuits and auxiliary power systems.

Industrial Control Electronics
Suitable for low-current control circuits, PLC-related equipment, controller power supplies and auxiliary electronics where switching noise may propagate through the AC input.
Switching Power Supplies
A 1A AC EMI filter can be installed at the power entry of low-power switching supplies to reduce conducted emissions generated by high-frequency switching.
Laboratory & Measurement Equipment
Test instruments and measurement systems may require power-line filtering to reduce interference entering or leaving sensitive electronics.
Communication Equipment
Compact power-line filters can help reduce conducted interference in communication terminals, network equipment and related low-current power supplies.
Medical Electronics
Low-leakage filter configurations can be evaluated for medical and safety-sensitive electronic equipment where both EMC performance and leakage-current limits must be considered.
PCB-Based Electronic Equipment
DAP1 provides a PCB-mount option where space is limited and the EMI filter must be integrated directly into the electronic assembly.
IEC Power-Entry Equipment
DAI1 and DBI5 are suitable where the equipment requires an IEC power inlet together with EMI filtering at the enclosure entry point.
VFD, Servo & Industrial Drive Control Circuits
A 1A filter is generally not intended for the main high-current power input of a VFD or servo drive.
However, it may be suitable for auxiliary power supplies, controllers, communication modules or other low-current circuits within the system.
Installation Guidelines for Better EMC Performance
Filter selection and installation should be considered together.
For better conducted EMI suppression:
Install the filter as close as practical to the AC power entry.
Keep unfiltered and filtered wiring physically separated.
Keep input and output wires short.
Avoid routing filter input and output cables parallel to each other.
Provide a short, low-impedance connection between the filter housing and metal chassis where grounding is required.
Avoid allowing unfiltered wiring to couple noise back into the filtered side.
Confirm leakage-current requirements before increasing Y-capacitance.
Re-test the equipment after installation under representative operating conditions.
If conducted emissions remain above the required limit, the filter should not automatically be replaced with a larger current rating. The noise frequency, attenuation requirement and installation layout should first be evaluated.
Standard vs Low-Leakage 1A EMI Filters
Standard EMI filters normally use line-to-ground capacitors to improve common-mode attenuation.
In applications with strict leakage-current requirements, a lower Y-capacitance configuration may be necessary.
This creates an engineering trade-off:
Higher common-mode attenuation ↔ Lower leakage current
For medical electronics, laboratory equipment and other safety-sensitive systems, DOREXS can evaluate the leakage-current requirement before selecting or modifying the filter circuit.
Custom 1A EMI Filter Solutions
When a standard filter cannot meet the electrical, mechanical or EMC requirements of the equipment, DOREXS can evaluate a custom design.
Customization can include:
Filter circuit configuration
Common-mode attenuation
Differential-mode attenuation
Leakage-current optimization
Terminal type
Wire length
Connector type
Mechanical dimensions
Housing configuration
PCB mounting structure
IEC power-entry configuration
OEM labeling
For an EMC troubleshooting project, providing the following information can significantly improve filter selection:
Input Voltage + Maximum Current + Equipment Type + EMC Test Curve + Failed Frequency Range + Installation Space + Leakage-Current Requirement
Quality, Testing & Compliance
DOREXS single phase EMI filter series are manufactured and inspected according to the requirements of the selected product and application.
Available evaluation and quality-control items may include:
Electrical performance inspection
Withstand-voltage testing
Insulation inspection
Leakage-current testing
Mechanical inspection
Insertion-loss evaluation
Final product inspection

Certifications and approvals vary by product series. Selected DOREXS EMI filters are available with cUL, CQC, CE and RoHS compliance options.
Always confirm certification requirements for the exact model selected for your project.
Related Single Phase EMI Filters
If 1A does not match the equipment load, choose the appropriate current rating based on the maximum operating conditions.
3A Single Phase EMI Filter
For low-power electronic and control equipment requiring additional current capacity.
6A Single Phase EMI Filter
Suitable for medium-power electronic equipment and industrial control systems.
10A Single Phase EMI Filter
For higher-current single phase equipment, switching power supplies and industrial electronics.
20A+ Single Phase EMI Filters
Available for industrial equipment requiring higher power handling and conducted EMI suppression.
Explore the complete Single Phase EMI Filter range to compare available current ratings and mechanical configurations.
Why Choose DOREXS?
DOREXS develops and manufactures EMI filtering and power-quality products for industrial and electronic equipment.
Our support includes:
Standard EMI filter products
OEM / ODM manufacturing
Custom EMI filter development
Electrical and mechanical customization
EMC troubleshooting support
Filter selection assistance
Technical documentation and datasheets
Rather than selecting a filter only from voltage and current, our engineers can evaluate the equipment architecture, noise characteristics and installation conditions when additional EMC support is required.
Frequently Asked Questions
What is a 1A single phase EMI filter?
A 1A single phase EMI filter is a power-line interference suppression device designed for single phase AC circuits with a rated current of approximately 1 amp. It is used to attenuate conducted common-mode and differential-mode noise while allowing normal AC power to pass to the load.
Can a 1A EMI filter be used on 220V or 230V equipment?
Yes, provided the selected filter model is rated for the equipment's operating voltage. DOREXS offers multiple 1A filter series for common 110/115–250VAC single phase systems.
Is a 1A filter suitable if my equipment normally draws 0.9A?
Selection should not be based only on normal current. Maximum continuous current, startup conditions, temperature and load variation should also be considered. If the equipment may exceed the filter rating, a higher-current model should be evaluated.
What is the difference between DAA1, DAA2 and DBA3?
All three can be used in single phase AC power-line filtering, but their mechanical structures, connection methods and filter configurations differ. DAA1 is a general-purpose compact chassis filter, DAA2 provides compact enhanced filtering options, and DBA3 provides more flexible industrial connection methods.
When should I use the DAP1 PCB EMI filter?
DAP1 is suitable when EMI filtering must be integrated directly onto the PCB and an external chassis-mounted filter is not preferred.
When should I use an IEC inlet EMI filter?
An IEC inlet filter such as DAI1 is useful when the AC power inlet and EMI filter should be integrated at the equipment power entry. DBI5 can be considered when additional switch or fuse integration is required.
Are low-leakage 1A EMI filters available?
Yes. Low-leakage configurations are available for selected series. The appropriate design depends on the required leakage-current limit and the amount of common-mode attenuation required.
Does a higher-current EMI filter provide better filtering?
Not necessarily. Current rating indicates how much load current the filter can safely carry; it does not by itself determine attenuation performance. Filter circuit structure, component values, noise frequency and installation conditions are also important.
How do I know how much insertion loss I need?
If the equipment has already undergone EMC testing, provide the conducted-emission curve, failed frequency range and exceedance level. These measurements help determine how much attenuation is required in the relevant frequency band.
Can DOREXS customize a 1A EMI filter?
Yes. Electrical parameters, leakage current, terminals, wiring, housing dimensions and filter configuration can be evaluated according to the equipment and EMC requirements.
Need Help Selecting a 1A EMI Filter?
Send your project requirements to the DOREXS engineering team:
- Voltage
- Maximum Current
- Equipment Type
- EMC Test Result or Failed Frequency
- Installation Space
- Connection Method
- Leakage-Current Requirement
We can evaluate whether a standard DAA1, DAA2, DBA3, DAP1, DAI1 or DBI5 configuration is suitable, or whether a custom EMI filter is required.