Model No: ACL

Three Phase Reactor

Three phase reactor
Input reactor
Output reactor
Quantity :
Contact Now

Three phase reactor (output reactor)

Reduce the dv/dt of the output voltage of the driver
Reduce the motor temperature and noise,
improve the motor insulation
Increase the motor service life
 

Technical specifications

  • Rated operating voltage: 3x380/480/690/1140V
  • Motor frequency: 50/60Hz
  • Inverter carrier frequency: 2-16kHz
  • Rated current: 5-1600A@40℃
  • Motor cable length: 30mmax@16kHz (see the derating curve on the next page)
  • Withstand voltage test: P->E4000VAC for 3sec / P->P4000VAC for 3sec
  • Reactance: 1%@380V/690/1140,50Hz / 1%@480V,60Hz
  • Protection level: IP00
  • Overload capacity: 1.6 times rated current 1min (once per hour)
  • Temperature range: -40℃ - +45℃ (full load operation)
  • Insulation level: T40/F(155°C)
Features and Benefits
  • Effectively reduce high output voltage dv/dt from 1GBT motor driver.
  • Protects motor coil insulation from premature aging and damage.
  • Significantly improves the service life of the motor.
  • Reduce interference propagation to adjacent equipment on the line.
Typical Application
  • Server Driver
  • Closed Loop Vector Driver
  • Motor driver with short cable
  • Pick and place machines
 

Three phase reactor (output reactor) selection parameter table

Model
Adaptation power
(KW)
Rated current
(A)
Voltage drop
Rated inductance
(mH)
Overall dimensions
Length*Width*Height
Installation size
(mm)
Pore diameter
(mm)
Weight
(Kg)
0CL-5(8)0.75(1.5)81%1.4120*85*13590*607*142.5
0CL-102.2101%0.7120*85*13590*607*142.6
0CL-103.7(4)101%0.7120*85*13590*607*142.6
0CL-155.5151%0.47155*130*135130*607*144.2
0CL-207.5201%0.35155*130*135130*607*144.2
0CL-3011301%0.234155*140*135130*707*144.7
0CL-4015401%0.175155*140*135130*707*145
0CL-5018.5501%0.14175*150*135150*807*147
0CL-6022601%0.117175*150*135150*807*147
0CL-8030801%0.0876200*160*165170*807*149.5
0CL-110371101%0.0637240*150*185200*8010*2014
0CL-125451251%0.055240*150*185200*8010*2014
0CL-150551501%0.0467240*165*185200*9010*2016
0CL-200752001%0.035240*170*185200*9510*2018
0CL-25090(93)2501%0.028240*180*185200*10510*2019
0CL-2801102801%0.026240*185*185200*11010*2021
0CL-3001323001%0.023240*185*185200*11010*2022
0CL-4001604001%0.0175240*200*185200*12010*2024.5
0CL-4501874501%0.016240*200*185200*12010*2025
0CL-500200(220)5001%0.014300*195*265260*10010*2035
0CL-6002506001%0.0117300*195*265240*10010*2036
0CL-7002807001%0.010300*205*265240*11010*2040
0CL-8003158001%0.0088300*220*265240*14010*2048
0CL-9003559001%0.008360*240*280275*13012*1856
0CL-100040010001%0.007360*260*320275*14012*1870
 


 
 
 

Three phase reactor (input reactor)

Reduce harmonics on the power supply side
Reduce commutation gaps
Limit inrush current
Economical and reliable solution to mitigate power supply interference
 

Technical specifications

  • Rated operating voltage: 3x380/480/690/1140V
  • Motor frequency: 50/60Hz
  • Rated current: 5-1600A@40℃
  • Withstand voltage test: P->E4000VAC for 3sec / P->P4000VAC for 3sec
  • Reactance: 2%@380V/690/1140,50Hz / 2%@480V,60Hz
  • Protection level: IP00
  • Overload capacity: 1.6 times rated current 1min (once per hour)
  • Temperature range: -40℃ - +45℃ (full load operation)
  • Insulation level: T40/F(155°C)
Features and Benefits
  • Ensure reliability, performance and long life for electrical users.
  • Suppress harmonics and commutation notching.
  • Help meet international power quality standards.
  • Reduce surge and peak currents.
  • Prevent nuisance trips due to power line voltage spikes.
  • Improve true power factor.
Typical Application
Motor drives and various adjustable speed drive systems, such as:Robotics、Machinery、Process automation equipment.

Three phase reactor (input reactor) selection parameter table

Model
Adaptation power
(KW)
Rated current
(A)
Voltage drop
Rated inductance
(mH)
Overall dimensions
Length*Width*Height
Installation size
(mm)
Pore diameter
(mm)
Weight
(Kg)
ACL-5(8)0.75(1.5)82%1.4120*85*13590*607*142.5
ACL-102.2102%0.7120*85*13590*607*142.6
ACL-103.7(4)102%0.7120*85*13590*607*142.6
ACL-155.5152%0.47155*130*135130*607*144.2
ACL-207.5202%0.35155*130*135130*607*144.2
ACL-3011302%0.234155*140*135130*707*144.7
ACL-4015402%0.175155*140*135130*707*145
ACL-5018.5502%0.14175*150*135150*807*147
ACL-6022602%0.117175*150*135150*807*147
ACL-8030802%0.0876200*160*165170*807*149.5
ACL-110371102%0.0637240*150*185200*8010*2014
ACL-125451252%0.055240*150*185200*8010*2014
ACL-150551502%0.0467240*165*185200*9010*2016
ACL-200752002%0.035240*170*185200*9510*2018
ACL-25090(93)2502%0.028240*180*185200*10510*2019
ACL-2801102802%0.026240*185*185200*11010*2021
ACL-3001323002%0.023240*185*185200*11010*2022
ACL-4001604002%0.0175240*200*185200*12010*2024.5
ACL-4501874502%0.016240*200*185200*12010*2025
ACL-500200(220)5002%0.014300*195*265260*10010*2035
ACL-6002506002%0.0117300*195*265240*10010*2036
ACL-7002807002%0.010300*205*265240*11010*2040
ACL-8003158002%0.0088300*220*265240*14010*2048
ACL-9003559002%0.008360*240*280275*13012*1856
ACL-100040010002%0.007360*260*320275*14012*1870
 
DOREXS offers more three phase reactor options, please contact us for a quote.