Model No: ACL
Three Phase Reactor
Three phase reactor
Input reactor
Output reactor
Input reactor
Output reactor
Quantity :
Subscribe to our Newsletter
![]() | Three phase reactor (output reactor) |
| Reduce the dv/dt of the output voltage of the driver | |
Reduce the motor temperature and noise, improve the motor insulation | |
| Increase the motor service life |
Technical specifications
- Rated operating voltage: 3x380/480/690/1140V
- Motor frequency: 50/60Hz
- Inverter carrier frequency: 2-16kHz
- Rated current: 5-1600A@40℃
- Motor cable length: 30mmax@16kHz (see the derating curve on the next page)
- Withstand voltage test: P->E4000VAC for 3sec / P->P4000VAC for 3sec
- Reactance: 1%@380V/690/1140,50Hz / 1%@480V,60Hz
- Protection level: IP00
- Overload capacity: 1.6 times rated current 1min (once per hour)
- Temperature range: -40℃ - +45℃ (full load operation)
- Insulation level: T40/F(155°C)
Features and Benefits
- Effectively reduce high output voltage dv/dt from 1GBT motor driver.
- Protects motor coil insulation from premature aging and damage.
- Significantly improves the service life of the motor.
- Reduce interference propagation to adjacent equipment on the line.
Typical Application
- Server Driver
- Closed Loop Vector Driver
- Motor driver with short cable
- Pick and place machines
| Model | Adaptation power (KW) | Rated current (A) | Voltage drop | Rated inductance (mH) | Overall dimensions Length*Width*Height | Installation size (mm) | Pore diameter (mm) | Weight (Kg) |
| 0CL-5(8) | 0.75(1.5) | 8 | 1% | 1.4 | 120*85*135 | 90*60 | 7*14 | 2.5 |
| 0CL-10 | 2.2 | 10 | 1% | 0.7 | 120*85*135 | 90*60 | 7*14 | 2.6 |
| 0CL-10 | 3.7(4) | 10 | 1% | 0.7 | 120*85*135 | 90*60 | 7*14 | 2.6 |
| 0CL-15 | 5.5 | 15 | 1% | 0.47 | 155*130*135 | 130*60 | 7*14 | 4.2 |
| 0CL-20 | 7.5 | 20 | 1% | 0.35 | 155*130*135 | 130*60 | 7*14 | 4.2 |
| 0CL-30 | 11 | 30 | 1% | 0.234 | 155*140*135 | 130*70 | 7*14 | 4.7 |
| 0CL-40 | 15 | 40 | 1% | 0.175 | 155*140*135 | 130*70 | 7*14 | 5 |
| 0CL-50 | 18.5 | 50 | 1% | 0.14 | 175*150*135 | 150*80 | 7*14 | 7 |
| 0CL-60 | 22 | 60 | 1% | 0.117 | 175*150*135 | 150*80 | 7*14 | 7 |
| 0CL-80 | 30 | 80 | 1% | 0.0876 | 200*160*165 | 170*80 | 7*14 | 9.5 |
| 0CL-110 | 37 | 110 | 1% | 0.0637 | 240*150*185 | 200*80 | 10*20 | 14 |
| 0CL-125 | 45 | 125 | 1% | 0.055 | 240*150*185 | 200*80 | 10*20 | 14 |
| 0CL-150 | 55 | 150 | 1% | 0.0467 | 240*165*185 | 200*90 | 10*20 | 16 |
| 0CL-200 | 75 | 200 | 1% | 0.035 | 240*170*185 | 200*95 | 10*20 | 18 |
| 0CL-250 | 90(93) | 250 | 1% | 0.028 | 240*180*185 | 200*105 | 10*20 | 19 |
| 0CL-280 | 110 | 280 | 1% | 0.026 | 240*185*185 | 200*110 | 10*20 | 21 |
| 0CL-300 | 132 | 300 | 1% | 0.023 | 240*185*185 | 200*110 | 10*20 | 22 |
| 0CL-400 | 160 | 400 | 1% | 0.0175 | 240*200*185 | 200*120 | 10*20 | 24.5 |
| 0CL-450 | 187 | 450 | 1% | 0.016 | 240*200*185 | 200*120 | 10*20 | 25 |
| 0CL-500 | 200(220) | 500 | 1% | 0.014 | 300*195*265 | 260*100 | 10*20 | 35 |
| 0CL-600 | 250 | 600 | 1% | 0.0117 | 300*195*265 | 240*100 | 10*20 | 36 |
| 0CL-700 | 280 | 700 | 1% | 0.010 | 300*205*265 | 240*110 | 10*20 | 40 |
| 0CL-800 | 315 | 800 | 1% | 0.0088 | 300*220*265 | 240*140 | 10*20 | 48 |
| 0CL-900 | 355 | 900 | 1% | 0.008 | 360*240*280 | 275*130 | 12*18 | 56 |
| 0CL-1000 | 400 | 1000 | 1% | 0.007 | 360*260*320 | 275*140 | 12*18 | 70 |
![]() | Three phase reactor (input reactor) |
| Reduce harmonics on the power supply side | |
| Reduce commutation gaps | |
| Limit inrush current | |
| Economical and reliable solution to mitigate power supply interference |
Technical specifications
- Rated operating voltage: 3x380/480/690/1140V
- Motor frequency: 50/60Hz
- Rated current: 5-1600A@40℃
- Withstand voltage test: P->E4000VAC for 3sec / P->P4000VAC for 3sec
- Reactance: 2%@380V/690/1140,50Hz / 2%@480V,60Hz
- Protection level: IP00
- Overload capacity: 1.6 times rated current 1min (once per hour)
- Temperature range: -40℃ - +45℃ (full load operation)
- Insulation level: T40/F(155°C)
Features and Benefits
- Ensure reliability, performance and long life for electrical users.
- Suppress harmonics and commutation notching.
- Help meet international power quality standards.
- Reduce surge and peak currents.
- Prevent nuisance trips due to power line voltage spikes.
- Improve true power factor.
Typical Application
Motor drives and various adjustable speed drive systems, such as:Robotics、Machinery、Process automation equipment.
| Model | Adaptation power (KW) | Rated current (A) | Voltage drop | Rated inductance (mH) | Overall dimensions Length*Width*Height | Installation size (mm) | Pore diameter (mm) | Weight (Kg) |
| ACL-5(8) | 0.75(1.5) | 8 | 2% | 1.4 | 120*85*135 | 90*60 | 7*14 | 2.5 |
| ACL-10 | 2.2 | 10 | 2% | 0.7 | 120*85*135 | 90*60 | 7*14 | 2.6 |
| ACL-10 | 3.7(4) | 10 | 2% | 0.7 | 120*85*135 | 90*60 | 7*14 | 2.6 |
| ACL-15 | 5.5 | 15 | 2% | 0.47 | 155*130*135 | 130*60 | 7*14 | 4.2 |
| ACL-20 | 7.5 | 20 | 2% | 0.35 | 155*130*135 | 130*60 | 7*14 | 4.2 |
| ACL-30 | 11 | 30 | 2% | 0.234 | 155*140*135 | 130*70 | 7*14 | 4.7 |
| ACL-40 | 15 | 40 | 2% | 0.175 | 155*140*135 | 130*70 | 7*14 | 5 |
| ACL-50 | 18.5 | 50 | 2% | 0.14 | 175*150*135 | 150*80 | 7*14 | 7 |
| ACL-60 | 22 | 60 | 2% | 0.117 | 175*150*135 | 150*80 | 7*14 | 7 |
| ACL-80 | 30 | 80 | 2% | 0.0876 | 200*160*165 | 170*80 | 7*14 | 9.5 |
| ACL-110 | 37 | 110 | 2% | 0.0637 | 240*150*185 | 200*80 | 10*20 | 14 |
| ACL-125 | 45 | 125 | 2% | 0.055 | 240*150*185 | 200*80 | 10*20 | 14 |
| ACL-150 | 55 | 150 | 2% | 0.0467 | 240*165*185 | 200*90 | 10*20 | 16 |
| ACL-200 | 75 | 200 | 2% | 0.035 | 240*170*185 | 200*95 | 10*20 | 18 |
| ACL-250 | 90(93) | 250 | 2% | 0.028 | 240*180*185 | 200*105 | 10*20 | 19 |
| ACL-280 | 110 | 280 | 2% | 0.026 | 240*185*185 | 200*110 | 10*20 | 21 |
| ACL-300 | 132 | 300 | 2% | 0.023 | 240*185*185 | 200*110 | 10*20 | 22 |
| ACL-400 | 160 | 400 | 2% | 0.0175 | 240*200*185 | 200*120 | 10*20 | 24.5 |
| ACL-450 | 187 | 450 | 2% | 0.016 | 240*200*185 | 200*120 | 10*20 | 25 |
| ACL-500 | 200(220) | 500 | 2% | 0.014 | 300*195*265 | 260*100 | 10*20 | 35 |
| ACL-600 | 250 | 600 | 2% | 0.0117 | 300*195*265 | 240*100 | 10*20 | 36 |
| ACL-700 | 280 | 700 | 2% | 0.010 | 300*205*265 | 240*110 | 10*20 | 40 |
| ACL-800 | 315 | 800 | 2% | 0.0088 | 300*220*265 | 240*140 | 10*20 | 48 |
| ACL-900 | 355 | 900 | 2% | 0.008 | 360*240*280 | 275*130 | 12*18 | 56 |
| ACL-1000 | 400 | 1000 | 2% | 0.007 | 360*260*320 | 275*140 | 12*18 | 70 |
DOREXS offers more three phase reactor options, please contact us for a quote.


Comprehensive score